Chapter 6 · Power & Light
How to choose a portable power station
A power station is a big battery with outlets. Two numbers decide almost everything: watt-hours for how long it lasts, and watts for what it can run. The rest is chemistry, charging and honest arithmetic.
Read first: Generator size
A portable power station is a lithium battery, a charger and an inverter in one box, with household outlets and USB ports on the front. It makes no exhaust, so unlike a generator it can sit indoors beside a bed or a desk. It also stores far less energy than a tank of fuel delivers, so choosing one means matching it carefully to what you actually need to run.
This guide explains the numbers on the spec sheet, how to estimate runtime honestly, what the battery chemistry means for how long the unit lasts, and how quickly you can refill it from the wall or the sun.
Watt-hours and watts: the two numbers that matter
Watt-hours (Wh) are the size of the tank: how much energy the battery holds. A 1,000 Wh battery could, in theory, supply 100 watts for 10 hours or 1,000 watts for one hour.
Watts (W) of continuous output are the size of the pipe: the most the station can deliver at any one moment. A station rated for 600 W continuous cannot run a 1,000 W coffee maker at all, however full its battery.
You need both. Capacity decides how long; output decides what. A small station with high output will run a microwave, briefly. A big battery with low output will run a lamp for days but nothing heavy.
Surge
Like a generator, a power station has a surge (peak) rating above its continuous rating, to start motors. ResMed's battery guide explains inverter ratings the same way: the continuous rating is what the inverter can deliver under sustained use without overload, and the surge or peak rating is what it can deliver for short periods, with the length of that period varying by manufacturer.
If something has a motor or compressor, compare its starting figure with the station's surge rating, not just its running watts with the continuous rating. The generator sizing guide explains why motors surge and how to add up a list of loads; the same arithmetic applies here.
How long will it run? The honest arithmetic
A battery never delivers all its rated watt-hours through the AC outlets, because the inverter that turns the battery's direct current into household alternating current loses some energy as heat. Jackery's own planning formula is:
Working time (hours) = capacity (Wh) × 0.85 ÷ the device's power (W)
Jackery adds that its stated durations come from laboratory data and that real use may vary. The 0.85 factor (85%) is a reasonable planning figure for AC loads; the calculator below uses it, and you can change it if your station's maker publishes its own. Devices charged from the USB or 12-volt ports skip the conversion to household AC, so they are not subject to that particular loss.
Power station runtime calculator (calculator online at minutemanalmanac.com/power/portable-power-stations/#calculator). Example: 1,000 Wh × 85% ÷ 150 W = 5.7 hours.
What common loads draw
| Load | Typical draw | Source and note |
|---|---|---|
| Cell phone charger | 20 W | EWEB worksheet |
| Laptop | 50–60 W | Virginia Cooperative Extension lists 50 W; EWEB lists 60 W |
| Refrigerator (frost-free, 16 cu ft) | 725 W nameplate, but on only part of the time | Virginia Cooperative Extension; see below |
| Refrigerator/freezer start-up | 700 W running plus 2,200 W additional starting | EWEB worksheet; typical, not your model |
| Color TV | 400 W (older sets); 120 W flat screen | EWEB; Virginia Cooperative Extension |
| Wi-Fi router and modem | Small | Read the watts or amps printed on each power adapter |
| CPAP machine | Varies widely by model and settings | Read your machine's manual; see below |
Refrigerators cycle. Virginia Cooperative Extension notes that a refrigerator, though plugged in all the time, cycles on and off, and suggests estimating its hours at full wattage as one third of the time it is plugged in. By that rule a 725 W refrigerator averages about 242 W, or about 5,800 Wh a day. That is a rough, high estimate for a nameplate figure; newer refrigerators may use much less. A better number for your own model is its EnergyGuide label, which the FTC says shows how much energy the appliance uses (an estimate based on typical use). If the label gives yearly kilowatt-hours, divide by 365 for a daily figure.
So on a 1,024 Wh station, 1,024 × 0.85 ÷ 242 gives about 3.6 hours of refrigerator by the extension rule, longer if your model uses less. That is why power stations suit a refrigerator only for bridging hours, not days, unless they are large or regularly recharged. For how long food stays safe with the door shut, see food safety in a power outage.
CPAP machines vary more than any other common load, and heated humidifiers and heated tubing are the big variable. ResMed's 2015 battery guide, which covers older models, called for a pure sine wave inverter of at least 300 W continuous and 500 W peak for its machines used with a humidifier, and warned that some of its heated humidifiers must not be used with inverters at all, because damage or serious injury can result. Check your current model's manual or ask the maker before relying on any battery, and test the setup on a normal night before an outage forces the question.
Battery chemistry: LiFePO4 vs NMC
Most power stations use one of two lithium-ion chemistries. The maker's spec sheet will say which.
| LiFePO4 (LFP, lithium iron phosphate) | NMC (lithium nickel manganese cobalt oxide) | |
|---|---|---|
| Energy for its weight | 90–120 Wh per kg | 150–220 Wh per kg |
| Cycle life | 2,000 and higher | 1,000–2,000 |
| Thermal runaway begins around | 270°C (518°F) | 210°C (410°F) typical |
| Strengths | Long cycle life, good thermal stability, tolerant of abuse | More energy in less weight |
| Weaknesses | Heavier for the same capacity; weaker in the cold | Shorter life; high charge levels promote thermal runaway |
All figures are from Battery University, which notes that cycle life depends on depth of discharge and temperature. For a unit that will sit in a closet for years and be cycled during outages, the longer life and greater thermal stability of LFP are strong reasons to prefer it; all four units compared below use it. NMC's advantage is weight, which matters most when you carry the unit.
Reading a cycle rating
A rating such as "3,000 cycles to 80% capacity" means that after 3,000 full charge and discharge cycles the battery is expected to hold 80% of its original capacity. It does not stop working there; it just holds less. Ratings are written to different endpoints, so compare like with like: Jackery rates the Explorer 1000 v2 to "70%+" capacity, while EcoFlow and Anker rate their units in the table below to 80%. A cycle count to 70% is not directly comparable with one to 80%.
Recharging: wall, solar and pass-through
From the wall, the RIVER 3 Plus, Explorer 1000 v2 and SOLIX C1000 quote 0–100% times from 50 minutes to about 1.6 hours. The DELTA Pro 3's figure is different: EcoFlow quotes 0–80% in 50 minutes, not a full charge. Some fast modes have to be switched on; Jackery, for example, quotes 1.58 hours standard and 50 minutes in its emergency charge mode.
From solar, the simplest estimate is capacity ÷ solar watts = hours of full sun. A 1,024 Wh station on a 200 W panel needs at least five hours of the panel's full rated output. In practice you get less than the rating:
- Panels are rated under Standard Test Conditions: 1,000 watts of sunlight per square meter at a cell temperature of 25°C (77°F). Carroll Electric Cooperative's guide points out that STC ratings seldom reflect real conditions, because panels run hotter than that and lose output as they heat. Its worked example loses 9% at a typical operating temperature.
- The same guide puts average peak sun hours in Arkansas and Missouri at about 4 a day, even where the sun is up for 7. Peak sun hours vary by place and season.
- Soiling, shading and wiring losses cut output further.
So a 200 W panel might bring in roughly 200 × 4 = 800 Wh on a good day in that climate, less after heat and other losses: less than one full charge of a 1 kWh station. The maximum solar input on the spec sheet is a ceiling, not a promise. It only matters if you own enough panel to reach it.
Pass-through and UPS. Most stations can charge while powering devices. Several also act as a UPS (uninterruptible power supply): left plugged into the wall with devices plugged into the station, they switch to battery when grid power fails. Makers quote the switchover time: 10 milliseconds or less for the EcoFlow units below, under 20 for the Jackery and Anker. Whether a given gap is short enough for a desktop computer or medical device depends on that device; check with its maker if it matters.
How to choose
Choosing a power station
- List what you need to run during an outage and its watts; total the ones that run at once
- Continuous output above that total; surge above the biggest starting load
- Capacity: daily watt-hours you need ÷ 0.85, times the days you want to cover between recharges
- LiFePO4 if it will be stored for years and cycled through outages
- Compare cycle ratings to the same endpoint (70% vs 80%)
- Solar input sized to the panels you actually own or will buy
- Weight you can carry: the 4 kWh unit below weighs over 113 lb
- If you run a CPAP, confirm the setup with your machine's manual and test it at home
Comparison
The four units below span the main sizes, from a 286 Wh unit for phones, lights and a router to a 4,096 Wh unit with 120/240-volt output, including a NEMA L14-30R outlet. Specs are the makers' own, read on their sites on the review date; nothing here was tested by the Almanac.
Portable power stations compared
Compare capacity (Wh) for how long, continuous output (W) for what it can run, and the cycle rating for how many years. Specs are the makers' own, as published on the date shown; recharge times are the makers' best-case figures.
EcoFlow
RIVER 3 Plus
- Capacity
- 286 Wh
- AC output (continuous)
- 600 W
- Surge
- 1,200 W
- Battery
- LiFePO4, 3,000 cycles to 80% capacity
- Weight
- 10.4 lb
- Max solar input
- 220 W (0–100% in as fast as 1.5 hr)
- AC recharge
- 380 W input, 0–100% in 60 min
- UPS switchover
- Under 10 ms
Jackery
Explorer 1000 v2
- Capacity
- 1,024 Wh on the page headline; 1,070 Wh in the page's spec table
- AC output (continuous)
- 1,500 W
- Surge
- 3,000 W
- Battery
- LiFePO4, 4,000 cycles to 70%+ capacity
- Weight
- About 23.8 lb
- Max solar input
- 400 W (two DC inputs combined)
- AC recharge
- 1.58 hr standard; 0–100% in 50 min in emergency charge mode
- UPS switchover
- Under 20 ms
Anker
SOLIX C1000
- Capacity
- 1,056 Wh
- AC output (continuous)
- 1,800 W
- Surge
- 2,400 W
- Battery
- LiFePO4, 3,000 cycles to 80%+ capacity
- Weight
- 28.44 lb
- Max solar input
- 600 W
- AC recharge
- 1,300 W max input, 0–100% in 58 min
- UPS switchover
- Under 20 ms
EcoFlow
DELTA Pro 3
- Capacity
- 4,096 Wh (expandable)
- AC output (continuous)
- 4,000 W at 120/240 V (6,000 W with X-Boost)
- Surge
- 8,000 W
- Battery
- LFP, 4,000 cycles to 80% capacity
- Weight
- 113.54 lb
- Max solar input
- 2,600 W total, 2 ports
- AC recharge
- 0–80% in 50 min (maker's fast-charge claim)
- UPS switchover
- 10 ms
Specs are the makers’ published figures, read November 2, 2026. “Used” marks gear the editor has used; the rest is compared on specs only. How we compare gear.
A note on capacity: Jackery's Explorer 1000 v2 page gives 1,024 Wh in its headline and 1,070 Wh in its spec table on the same day. We have listed both rather than choose one.
Power station or generator?
A power station is quiet, makes no fumes and can run indoors, but its energy is limited to what the battery holds until you recharge it. A generator keeps supplying power for as long as you have fuel, but must run outdoors, well away from the house, because of carbon monoxide. Many households use both: the generator by day, the power station overnight for the bedroom loads. See what size generator you need, and if you want either to feed house circuits, transfer switches and interlock kits.
Sources
- Jackery — Explorer 550 FAQ: working time formula (hosted by The Home Depot)
- Battery University — BU-205: Types of Lithium-ion
- Virginia Cooperative Extension — Estimating Appliance and Home Electronic Energy Use
- EWEB (Eugene Water & Electric Board) — Generator Sizing Considerations
- Carroll Electric Cooperative — A Guide to Solar Panel Ratings
- ResMed — Battery guide (2015)
- FTC — How to Use the EnergyGuide Label to Shop for Home Appliances
- EcoFlow — RIVER 3 Plus specifications
- Jackery — Explorer 1000 v2 specifications
- Anker SOLIX — C1000 specifications
- EcoFlow — DELTA Pro 3 specifications